Short answer: a GFCI trips because it is measuring current leaving the circuit through something other than the neutral — usually moisture, a failing appliance, a damaged cord, too much wiring on one protected circuit, or a worn-out GFCI device itself. It is doing its job. The fix is to find where the leakage is coming from, not to stop resetting it or replace it with a plain outlet.
A GFCI compares the current going out on the hot conductor with the current coming back on the neutral. If those two do not match by a few milliamps, some current is returning by another path — through water, through a metal enclosure, or through a person. It opens in a fraction of a second. That imbalance threshold is far below what a breaker cares about, which is why a GFCI can trip on a circuit that is nowhere near overloaded.
Unplug everything on the affected outlets, reset the GFCI, then plug items back in one at a time and wait. If it holds until a specific appliance goes in, you have found your answer and it is an appliance problem, not a wiring problem. Remember that one GFCI often protects several downstream outlets — the tripping outlet in the bathroom may be fed by a GFCI in the garage or on an exterior wall, so look there before assuming the device is missing.
Also press the TEST button on each GFCI in the house once in a while. If pressing TEST does not cut power, or if the RESET button will not stay in with nothing plugged in at all, the device is done and should be replaced.
We map what the GFCI actually feeds, isolate the circuit section by section, and measure leakage rather than guess. Most of the time we can tell you within an hour whether you are looking at a bad device, a wet box, a wiring problem in the wall, or an appliance that needs to be retired. If we find a broader issue — no GFCI protection where current code requires it, or a circuit that was extended without a permit — we will show you what we found and what it takes to correct it.
B and D Electric LLC is a family-run Phoenix electrical contractor, Arizona ROC 361086, with two owners and over 40 years of combined electrical experience. We are insured at $1,000,000 per occurrence / $2,000,000 aggregate through Clear Spring Property & Casualty and bonded through RLI Surety. Call (480) 828-1181 and describe what trips and when.